江南制冷
Language

News

Current location:
Homepage
>
>
>
The classic and practical fan coil introduction knowledge, you are worth collecting!

The classic and practical fan coil introduction knowledge, you are worth collecting!

  • Categories:Industry News
  • Author:
  • Origin:制冷百科
  • Time of issue:2020-03-13
  • Views:767

(Summary description)

The classic and practical fan coil introduction knowledge, you are worth collecting!

(Summary description)

  • Categories:Industry News
  • Author:
  • Origin:制冷百科
  • Time of issue:2020-03-13
  • Views:767
Information
1. Brief introduction and characteristics of fan coil unit:
Fan coils are ideal end products for central air conditioning. Fan coils are widely used in hotels, office buildings, hospitals, commercial and residential, scientific research institutions and other places. Its working principle is that the fan cools or heats indoor air or outdoor mixed air through a surface cooler and sends it into the room, so that the indoor temperature is lowered or raised to meet people's comfort requirements.
 

 

Main advantage:
Small size; high efficiency; low noise; low energy consumption. The body structure is exquisite, compact, sturdy and durable. The coil tube is made of high-quality galvanized sheet casing. The condensate water pan is integrally formed by a molding process. There are no welds, solder joints, and fire-proof insulation materials that are integrally connected to the water pan.
 

 

Main disadvantages:
Since this method is only based on convection heat exchange, which makes the indoors less than the best comfort level, it is only suitable for places where people stay for a short time, such as offices and hotels, and not for ordinary residences. Due to the addition of fans, the construction cost and operating cost are increased, and the maintenance and management of the equipment are also more complicated.
 

 

2. Working principle and common styles:
Relying on the forced action of the fan, the air passes through the coil, and the air in the room is continuously recirculated in the unit, so that the air is cooled (heated) after passing through the cold water (hot water) coil to keep the room temperature constant.
 

 

Common styles:
  • Horizontal concealed (with return air box) fan coil unit;

  • Horizontal surface mounted fan coil unit;

  • Vertical concealed fan coil unit;

  • Vertical surface mounted fan coil unit;

  • Cassette two-outlet fan coil unit;

  • Cassette four-outlet fan coil unit;

  • Wall-mounted fan coil unit;

  • Cabinet type fan coil unit.

 

 

According to the form:
There are five types: horizontal concealed installation, horizontal exposed installation, vertical concealed installation, vertical exposed installation, and cassette type.
 

 

According to thickness:
Ultra-thin, ordinary type.
 

 

According to the presence or absence of a condensate pump:
Ordinary type, luxurious type.
 

 

 

 

According to the static pressure of the unit:
0Pa, 12Pa, 30Pa, 50Pa, 80Pa (external static pressure).
 

 

According to the number of pipes:
Two rows of tubes, three rows of tubes.
 

 

By standard:
Two controls, four controls.
 

 

Two rows of tubes, three rows of tubes:
Second row: There are two rows of copper pipes, each row of 8 pieces, a total of 16 copper pipes.
Three rows: There are three rows of copper pipes, each row has 8 copper pipes, a total of 24 copper pipes.
The rows of fan coils refer to the number of copper pipes of the fan coil surface cooler. The more copper pipes there are, the better the cooling effect.
 

 

Two control, four control:
Two controls: ordinary fan coils use cold water for cooling in summer and hot water for heating in winter
Four control: mostly used in some more luxurious places, hot and cold water can be used at the same time, that is, some rooms can be cooled according to needs, and some rooms can be heated
 

 

control method:
Simple control: use the three-speed switch to directly manually control the three-speed conversion and start-stop of the fan
 

 

Temperature control: The thermostat automatically controls the opening and closing of the STV series electric two/three-way valve according to the comparison and calculation of the set temperature and the actual detected temperature; directly controls the three-speed conversion and start-stop of the fan, so as to control the water flow or The air volume achieves the purpose of constant temperature
 

 

3. The impact of parameter changes on performance:
 

 

1. The air volume of the fan coil unit is constant, the temperature of the water supply is constant, and when the water supply volume changes, the cooling capacity changes with the change of the water supply volume. [This article source: Refrigeration Encyclopedia Public Number], according to the performance statistics of some fan coil products, when the water supply temperature is At 7°C, when the water supply is reduced to 80%, the cooling capacity is about 92% of the original, indicating that when the water supply changes, the impact on the cooling capacity is relatively slow.

 

 

 

2. The temperature difference between the supply and return water of the fan coil unit is constant. When the temperature of the water supply increases, the cooling capacity decreases. According to statistics, when the temperature of the water supply rises by 1℃, the cooling capacity decreases by about 10%. The higher the water supply temperature, the greater the reduction. Large, the dehumidification capacity decreases.
 

 

3. When the water supply condition is constant, when the air volume of the fan coil is changed, the cooling capacity and the air handling enthalpy difference will change. Generally, the cooling capacity decreases and the enthalpy difference increases, and the power consumption of the fan per unit cooling capacity does not change much.
 

 

4. When the temperature difference between the inlet and outlet of the fan coil increases, the water volume decreases, and the heat transfer coefficient of the heat exchange coil decreases. In addition, the heat transfer temperature difference has also changed. Therefore, [this article source: Refrigeration Encyclopedia Public Number], the cooling capacity of the fan coil decreases with the increase in the temperature difference between the supply and return water. According to statistics, when the water supply temperature is 7°C, the supply and When the return water temperature difference is increased from 5℃ to 7℃, the cooling capacity can be reduced by about 17%.

Keyword:

Scan the QR code to read on your phone

relevant information

11-19

What problems should be paid attention to when transforming a warehouse into a cold storage

In order to store fruits for a long time, many vendors have transformed their original warehouses into fruit fresh-keeping cold storages. However, there are still big differences between warehouses and cold storages. So what issues should be paid attention to when transforming warehouses into cold storages! 1. It is necessary to consider whether the thermal insulation structure of the original warehouse is suitable for cold storage and preservation. Generally, the exterior of the warehouse is made of polystyrene double-layer color steel plates or rock wool boards. This type of structure is not suitable for refrigeration, preservation, and quick-freezing. It is only suitable for storage at 15°C. If it is lower than 15°C ℃, it is recommended to add polyurethane double-sided color steel warehouse board of corresponding thickness in the warehouse. Generally, this kind of warehouse board has good heat preservation effect and high fire resistance level. 2. The bearing capacity of the steel structure at the top of the original warehouse needs to be considered. Some warehouse roofs use arc-shaped round pipe structures, which have limited force and cannot withstand large-area cold storage roofs. This is also the need to pay attention to the transformation. 3. Some warehouses are simple cement floors and are not suitable for reconstruction and construction of cold storage. Therefore, ground insulation treatment needs to be considered. If the temperature is below 0℃, the ventilation pipe must be pre-embedded to prevent the foundation from sinking due to the low temperature. In this way, the bottom material should be extruded board, air- and moisture-proof layer, concrete layer, etc., in short, moisture, water and heat preservation should be done. 4. Consider the carrying capacity of power equipment. Since it used to be an ordinary warehouse, the original power may not take into account the use of later equipment, so we also need to pay attention to power cables. Electricity for cold storage generally requires 380V commercial electricity. Maungsheng Refrigeration does not recommend using 220V for cold storage construction, even small fresh-keeping cold storage is not recommended. The specific cold storage construction uses 200V electricity or 380V electricity can see detailed analysis. 5. It is necessary to consider whether the warehouse can penetrate the wall hole, because the cold storage needs to be connected with the internal unit during installation to ensure its freezing effect. 6. The design of cold storage shelves also needs to consider other factors, such as: the selection of welding electrodes in the cold storage should correspond to the material and welding process requirements of the welding base material and ensure the welding quality of the welds. The characteristics of frosting in the cold storage should be considered, the weight gain should be appropriately considered when calculating the shelf selection, and the customer's refrigeration and defrosting process should be considered for the corrosion resistance of the structural spray coating.
11-19

Precautions for the use of cold storage

Cold storage refers to constant temperature storage air-conditioning equipment for food, dairy products, meat, aquatic products, chemicals, medicine, seedlings, scientific experiments, etc. In fact, the cold storage is very similar to the refrigerator, but the area of the cold storage is much larger than that of the refrigerator, and the temperature range is wider than that of the refrigerator. The ultra-low temperature freezing of the cold storage is not reachable by the refrigerator, but they have the same refrigeration principle. The following Lengdi Refrigeration will explain to you the precautions for using the cold storage! (1) Under normal circumstances, it is not recommended to manually control the temperature of the refrigeration switch to ensure the appropriate temperature for automatic operation; (2) Regularly check the operation control and temperature changes of the unit by the control cabinet,
01-10

The importance of cold storage design

Usually, customers will ask the cold storage engineering company to produce a detailed cold storage design plan in the initial stage of consulting the construction of the cold storage. Especially for large-scale cold storage, the design plan is the most important part of the entire cold storage construction process. Today, I will introduce to you the importance of cold storage design.
Previous page
1
2
6

hotline

13622664361

Tel: 13622664361, 0757-26325710, 26325712, 26325713
Fax: 0757-26325711

After-sales service: 0757-26325714
E-mail: jining@sdjinling.com

Address: No.7, Liangchang Industrial Zone, Duning, Beibai Town, Shunde District, Foshan City, Guangdong Province

手机站

Scan and follow the official account

Copyright: Jinling Kitchen Equipment Co., Ltd., Shunde District, Foshan City    粤ICP备05037478号-1     Technical support: www.300.cn │   Shunde